HTEK11CB/HTCLB

Live End Feed with Circuit Breakers for 277V Two-Circuit Track (Right Polarity)

Powers track system from the end of a run. Current Limiter can be used as an on/off switch. Breaker features a “tripped” condition indicator.

Why and when to use a Nora Current Limiter?
Use Nora’s track current limiter in tough watts per square foot. Commercial, residential and NEC calculate the wattage of a line voltage track run by the length of the run, not by the wattage consumed. NEC applies 45 watts per foot regardless of actual load.

Example: (3) 39W Fixtures on a 20′ run would be calculated at 900W (20′ at 45 Watts)

With Nora’s 1 amp current limiter track feed, this run is now limited to 277 watts. A savings of 623 watts in the watts per square foot.

Compatible Track System: Two-Circuit / Two-Neutral (HTEK)

Polarity: Right Polarity

Input Voltage: 277V

Current Limiter: 0.5A, 1A, 2.5A, 5A, 10A, 15A

Finish: Black or White

Downloads

Downloads

• Specification Sheet

• Instruction Sheet